RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

Brand Name : BIOVANTION

Place of Origin : China

MOQ : 50kits

Assay Time : 2 Hours

Assay Type : Immunological Assay

Detection Limit : Low

Expiration Date : 18 months

Organism : Homo sapiens (Human)

Product Type : Research Test Kit

Reactivity : Highly reactive

Sample Type : Biological Samples

Sample Volume : 50 µL

Specificity : High Specificity

Test Sample Type : Serum, Plasma

Test Species : Human

Time To Results : Rapid Results

Contact Now

Research test for the quantitative determination of SAA Kit in human serum on automate chemistry analyzers

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

SAA (Serum Amyloid A) is is an acute-phase protein. During
inflammation, infectious and non-infectious diseases, its concentration in the blood can rise sharply within a few hours, and can rise to 1000 times the initial concentration. SAA is
related to HDL, and it can It regulates the metabolism of HDL
during inflammation. A particularly important feature of SAA is
that its degradation products can be deposited in different organs
in the form of amyloid A fibrils. This is a serious complication in
chronic inflammatory diseases; Elevated serum amyloid A is also
seen in atherosclerosis, diabetic nephropathy, acute myocardial
infarction, coronary heart disease, and chronic kidney disease

Components

Contents components Concentration

R1

PBS Buffer NaCl Surfactant

Antiseptic

0.1 mol/L Titer Titer

Titer

R2

Latex particles coated with SAA antibody

PB Buffer NaCl Surfactant

Antiseptic

>0.5mg/L

0.1 mol/L Titer Titer

Titer

Calibrator

/Control

SAA

Bovine serum albumin NaCl

Surfactant

Antiseptic

See Value Sheet Titer

Titer Titer

Titer

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

【Procedure】

Reagent preparation:

R1: Ready for use; R2: Ready for use. Wavelength:570nm Temperature:37℃

Direction: Increase

Blank Tube Calibration Tube Sample Tube
Sample 2ul
Calibrator 2ul
Deionized water 2ul
R1 200μl 200μl 200μl
Mix, incubate at 37℃ for 5 minutes.
R2 40μl 40μl 40μl

Mix, incubate at 37℃ for 5 minutes, zero setting for blank

tube, read the absorbance A calibrator and A sample

Calibration

It is recommended to use the SAA Calibrators for calibration. Dissolve the lyophilized SAA calibrator with 1ml distilled water, and dilute to 6 calibrators as follows,

Dilute 1 2 3 4 5 6
CAL (μl) 200 100 50 50 25 0

Normal

Saline (μl)

0 100 150 350 375 200
ratio 1 1/2 1/4 1/8 1/16 0

Calibration Method:Spline or other non-linear method

Quality control

It is recommended to use the SAA Quality Control level 1 and level 2 for daily quality control.

Two levels of controls should be assayed at least once a day. Values obtained should fall within a specified range.

Each laboratory should establish its own internal Quality Control scheme and procedures for corrective action if controls do not recover within the acceptable tolerances.

Calculation:

The analyzer automatically calculate the analyte concentration of each sample.


Product Tags:

Research Use Only Test Kit

      

Ruo Diagnostic Kit

      

Ruo Assay Kit

      
Quality RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric) wholesale

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric) Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Biovantion Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)