Sign In | Join Free | My qualitytoyschina.com
China Biovantion Inc. logo
Biovantion Inc.
Concentrate on IVD reagents
Verified Supplier

4 Years

Home > RUO Test Kit >

Human TLR4 RUO ELISA Assay Kit For Medical Diagnosis RUO Research Use Only

Biovantion Inc.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Human TLR4 RUO ELISA Assay Kit For Medical Diagnosis RUO Research Use Only

  • 1
  • 2

Brand Name : Biovantion

Model Number : BVTE159

Certification : ISO13485

Place of Origin : China

MOQ : 10

Price : Negotiable

Payment Terms : TT 100% PAYMENT

Supply Ability : 100000

Delivery Time : 7-15 days

Packaging Details : CARTON

Storage Temperature : 2-8°C

Product Name : Human TLR4 RUO ELISA Assay Kit

Sensitivity : High

Shelf Life : 18 Months

Test Type : ELISA

Specimen : Serum 50μl

Kit Size : 96 Tests

Applications : Medical Diagnosis

Contact Now

Purpose:

This kit allows for the determination of TLR4 concentrations in Human serum..

Principle of the assay

The kit assay Human TLR4 level in the sample, use Purified Human TLR4 antibody to coat microtiter plate wells, make solid-phase antibody, then add TLR4 to wells, Combined TLR4 antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Completely, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TLR4 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Technical Parameters:

Product Name: Human TLR4 RUO ELISA Assay Kit
Country of Origin: China
Sample Type: Serum, Plasma
Specimen: Serum 50μl
Storage Temperature: 2-8°C
Shelf Life: 6 Months
Sensitivity: High
Assay Time: 1 Hour
Kit Size: 96 Tests
Applications: Medical Diagnosis
Human TLR4 RUO ELISA Assay Kit For Medical Diagnosis RUO Research Use OnlyHuman TLR4 RUO ELISA Assay Kit For Medical Diagnosis RUO Research Use Only

Materials provided with the kit:

1 wash solution 20ml×1bottle 7 Stop Solution 6ml×1 bottle
2 HRP-Conjugate reagent 6ml×1 bottle 8 Standard(32ng/mL) 0.5ml×1 bottle
3 Microelisa stripplate 12well×8strips 9 Standard diluent 1.5ml×1bottle
4 Sample diluent 6ml×1 bottle 10 Instruction 1
5 Chromogen Solution A 6ml×1 bottle 11 Closure plate membrane 2
6 Chromogen Solution B 6ml×1 bottle 12 Sealed bags 1

Specimen requirements

  • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
  • Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

Assay procedure

  • Dilute and add sample:Dilute Original density Standard as follow table:
16ng/mL 5 Standard 150μl Original density Standard+150μl Standard diluent
8ng/mL 4 Standard 150μl 5 Standard+150μl Standard diluent
4ng/mL 3 Standard 150μl 4 Standard+150μl Standard diluent
2ng/mL 2 Standard 150μl 3 Standard +150μl Standard diluent
1ng/mL 1 Standard 150μl 2 Standard +150μl Standard diluent

2. Add sample:Set blank wells separately (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. Add 50μl of standard to Microelisa stripplate, add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

3. Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.

4. Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.

5. Washing: Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

6.Add enzyme: Add HRP-Conjugate reagent 50μl to each well, except blank well.

7. Incubate: Operation with 3.

8. Washing: Operation with 5.

9.Color: Add Chromogen Solution A 50ul and Chromogen Solution B 50ul to each well, evade the light preservation for 10 min at 37℃

10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).

11.Assay: take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

Calculate

Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.


Product Tags:

RUO ELISA Assay Kit

      

Human TLR4 ELISA Assay Kit

      

Medical Diagnosis ELISA Assay Kit

      
Quality Human TLR4 RUO ELISA Assay Kit For Medical Diagnosis RUO Research Use Only wholesale

Human TLR4 RUO ELISA Assay Kit For Medical Diagnosis RUO Research Use Only Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Biovantion Inc.
*Subject:
*Message: